Finest F1005 2 Channel Handheld Oscilloscope Kit

Finest F1005 2 Channel Handheld Oscilloscope Kit

$1,974.50 incl. GST
Brand:
Product Code: F1005
Availability: Pre-Order
Viewed 13064 times

Digital Oscilloscope

Sample rate:  25 Mega sample/second 
Record length:  1000 Points 
Update rate:  Real time, Roll 
Accuracy:  ± (0.1% + 1 pixel) 
Sweep rate:  1 µs to 50 sec in a 1, 2, 4 sequence (Scope mode 4 s to 24 Hours in a 1, 2, 4 sequence)
Band width:  DC to 4 MHz; -3 dB 
Resolution:  8 bit 
Channels:  2 Channel 
Coupling:  AC, DC, GND 
Input Impedance:  1 Mohm / 70 pF 
Maximum Input Voltage:  300 V 
Volt/Division:  50 mV to 100 V in a 1, 2, 4 sequence 
Accuracy:  ± 3 % 
Trigger Source:  CH A, CH B, TRIGGER (External trigger) 
Sensitivity (CH A):  < 1.0 div to 4 MHz 
Sensitivity (Trigger):  0.2 V p-p 
Modes:  Single shot, Normal, Auto 
Coupling:  AC, DC 

Slope:  Rising and falling edge 

 

Graphing Multimeter


RPM Measurement
4 Cylinder: Range - 120 - 20000 RPM; Accuracy 2 RPM 
2 Cylinder: Range - 60 - 10000 RPM; Accuracy 2 RPM 
Frequency Measurement
Accuracy: ± (0.1 % + 3 d)  
% Duty
Range 2.0 % ~ 98 %
Dwell
Range 3.6 ° ~ 356.4 °
Pulse Width
Range 2 µs ~ 450 ms (Pulse Width)
DC Voltage Measurement
Accuracy: ± (0.3 % + 4 d) 
Input Impedance : >10 MΩ  
AC Voltage Measurement
Accuracy: 40 Hz ~ 400 Hz:  ± (0.4 % + 4 d) ; 400 Hz ~ 10 kHz: ± (2.4 % + 4 d)
Input Impedance : > 10 MΩ  
(AC+DC) Voltage Measurement
Accuracy: 40 Hz ~ 400 Hz:  ± (0.8 % + 4 d) 
400 Hz ~ 10 kHz: ± (3.0 % + 4 d)  
Ohm Measurement
Accuracy:  
500 Ω; 4 kΩ; 50 kΩ; 500 kΩ:  ± (0.4 % + 4 d) 
5 MΩ:  ± (0.75 % + 4 d);  30 MΩ: ± (0.75 % + 10 d) 
Continuity Test
Test Voltage: 1.2 V    Threshold: Approx. 70 Ω   Response time: 1 ms 
Diode Test
Range: 2.0 V    Open Circuit Voltage: 3.0 V    Accuracy: ± (2.0 % + 4 d)                                                                                               

Temperature Measurement
Range: -50 °C to 1300 °C    Resolution: 0.1 °C    Accuracy: ± 3 °C 
Range: -58 °F to 2372 °F    Resolution:  0.1 °F    Accuracy: ± 4.4 °F 
DC Ampere Measurement (Current Probe Output)
Range:  30 mA ~ 20 A:  Accuracy ± (1.4 % + 20 mA) 
Range:  100 mA ~ 40 A:  Accuracy ± (2.0 % + 20 mA) 
Range:  40 A ~ 60 A:  Accuracy ± (4.0 % + 0.3 A) 
AC Ampere Measurement (Current Probe Output)
Range: 30 mA ~ 10 A   Accuracy: ± (2.0 % + 20 mA) @ 40 Hz ~ 1 kHz; ± (4.0 % + 30 mA) @ 1 kHz ~ 4 kHz 
Range: 100 mA ~ 40 A  Accuracy:  ± (2.0 % + 20 mA) @ 40 Hz ~ 1 kHz;   ± (6.0 % + 30 mA) @ 1 kHz ~ 4 kHz 
Range: 40 A ~ 60 A   Accuracy:  ± (8.0 % + 0.3 A)   

 

Coming soon

Product Description

Finest Two Channel Handheld Oscilloscope

1005 Automotive Scope/GMM  

The 1005 Automotive Scope/GMM (Graphing Multi-meter) is a powerful and versatile scope meter for trouble shooting automotive electronics.

Features

25 Mega-Sample/Second (one channel minimum sample rate for rapid data updates.

Lab scope signal patterns.

True RMS Graphing Multi-meter measurements and graphs.

Unique "Glitch Snare" mode: captures, displays and optionally saves abnormal signal patterns in the Scope mode of COMPONENT TESTS only when they occur.

Reset tests that enable the user to check the majority of automotive sensors, actuators and systems easily and quickly.

Powerful built-in reference information for each preset test which includes a test procedure showing how to connect to the circuit, a normal reference signal pattern, theory of operation and trouble-shooting tips.

Menu-driven interface has automatic configurations for most of non-preset tests, so that you will find the 1005/1006 Automotive Scope/GMM is easy to use.

The Secondary Ignition Single function displays the waveform along with Spark Voltage, Burn Time, Burn Voltage and RPM.

The diesel function allows you to set injection pump timing and RPM using the optional diesel accessories.

Supports Dynamic Compression Test.

USB interface supports updates for code and data.